Bio Air Clean Technologies manufactures NSF/ANSI 49, and EN12469 certified Class I and Class II Biosafety Cabinets (BSCs) that provide personnel, product, and environmental protection through the use of laminar air flow and HEPA filtration when looking to obtain optimum control over product quality while reducing the potential for exposure. We offer a range of ergonomically designed bench top and console models that can either be recirculated back into the laboratory environment or into a facility exhaust system through the duct work.
A Biosafety Cabinet is a ventilated enclosure offering protection to the user, the product and the environment from aerosols arising from the handling of potentially hazardous micro-organisms. The continuous airflow is discharged to the atmosphere via a HEPA filter. Biosafety cabinets are divided into three classes: I, II and III. Class I provides protection for the user and surrounding environment, but no protection for the sample being manipulated. Class II provides protection for the user, environment and sample, and is divided into four types: A1, A2, B1 and B2. Class II. A Class II cabinet is defined as a ventilated cabinet for personnel, product and environmental protection for microbiological work or sterile pharmacy compounding Biosafety level 3 (BSL-3) is applicable to clinical, diagnostic, teaching, research, or production facilities where work is performed with agents that may cause serious or potentially lethal disease through inhalation, to the personnel, and may contaminate the environment.
Biological safety cabinets reduce the risk of airborne infection by reducing the escape of aerosolized infectious agents into the laboratory environment. In addition to protecting workers, some biological safety cabinets protect the work inside the cabinet from airborne contamination (product protection). Biological safety cabinets minimize contact between the operator and pathogens through the use of directional airflow, HEPA filtration of supply and/or exhaust air, and, in some cases, a physical barrier such as a plastic or glass shield.
Bio Air Clean Technologies manufactures is an effective primary engineering control in obtaining the optimum product quality while reducing the potential for exposure of both product and personnel to airborne biological or particulate chemical agents in low to moderate rist-hazard research and drug preparation. Bio air clean technologies offers economical operation through the use of an ultra-high efficiency motor to maximize filter life and monolithic silicone-free construction for long product life all for an affordable price
Model No. | External Dimension | Internal Dimensions | Airflow Velocity (Inflow) | Electrical |
---|---|---|---|---|
BACT-1200 | 1340 x 731 x 1395 mm (52.8” x 28.8” x 55.0”) |
1220 x 660 x 670 mm (48.0” x 26.0” x 26.4”) |
0.85 m/s (167 fpm) |
230 V 50/60 Hz |
Product Number | Superstructure-Exterior Dimensions | BASE STAND | |||||
---|---|---|---|---|---|---|---|
Width(mm) | Depth(mm) | Height(mm) | Dimensions in inches | Series type | Types of stand | Size and range of motion | |
BACT | 1100 | 815 | 1610 | 43.3"* 32.1" * 63.4" | 1100 Series | Manual Adjust | 711mm-838mm(28"-35") range of motion |
BACT | 1100 | 815 | 1610 | 43.3"* 32.1" * 63.4" | 1100 Series | Elec Adjust | 711mm-838mm(28"-35") range of motion |
BACT | 1400 | 815 | 1610 | 55.1"* 32.1" * 63.4" | 1400 Series | Manual Adjust | 711mm-838mm(28"-35") range of motion |
BACT | 1400 | 815 | 1610 | 55.1"* 32.1" * 63.4" | 1400 Series | Elec Adjust | 711mm-838mm(28"-35") range of motion |
BACT | 1400 | 815 | 1610 | 55.1"* 32.1" * 63.4" | 1400 Series | Manual Adjust | 711mm-838mm(28"-35") range of motion |
BACT | 1400 | 815 | 1610 | 55.1"* 32.1" * 63.4" | 1400 Series | Elec Adjust | 711mm-838mm(28"-35") range of motion |
BACT | 1700 | 815 | 1610 | 66.9"* 32.1" * 63.4" | 1700 Series | Manual Adjust | 711mm-838mm(28"-35") range of motion |
BACT | 1700 | 815 | 1610 | 66.9"* 32.1" * 63.4" | 1700 Series | Elec Adjust | 711mm-838mm(28"-35") range of motion |
BACT | 2200 | 815 | 1610 | 78.7"* 32.1" * 63.4" | 2000 Series | Elec Adjust | 711mm-838mm(28"-35") range of motion |
BACT | 2200 | 815 | 1610 | 78.7"* 32.1" * 63.4" | 2000 Series | Manual Adjust | 711mm-838mm(28"-35") range of motion |
BACT | 2200 | 815 | 1610 | 78.7"* 32.1" * 63.4" | 2000 Series | Elec Adjust | 711mm-838mm(28"-35") range of motion |
BACT | 2200 | 815 | 1610 | 78.7"* 32.1" * 63.4" | 2000 Series | Manual Adjust | 711mm-838mm(28"-35") range of motion |
Options | Product Description |
BACT | 102MM(5") CASTER SET(Duratex Phenolic wheel with fornt lcking wheels) |
BACT | UV GERMICIDAL LIGHT |
BACT | IV POLE |
BACT | IV POLE |
BACT | IV POLE |
BACT | IV POLE |
BACT | THIMBLE CONNECTION FOR A2 ASSEMBLY 1100 SERIES* |
BACT | THIMBLE CONNECTION FOR A2 ASSEMBLY 1400 SERIES* |
BACT | THIMBLE CONNECTION FOR A2 ASSEMBLY 1700 SERIES* |
BACT | THIMBLE CONNECTION FOR A2 ASSEMBLY 2000 SERIES* |
BACT | ADJUSTABLE FOOTREST 76MM TO 279MM ("3 TO 11") |
BACT | Service fitting (specfiy service desired), Field Installed |
BACT | bUTTERFLY DAMPER, 12in Dia., Type 304 st/stc, Manual Control |